Worked example: 500 units a month in Lahore
A home using 500 units a month uses about 16.7 units a day. Lahore's average output in our data is 4.2 units per kW per day, after typical losses. With 585 W panels:
| Goal | System | Panels | Inverter | Output / month | Roof |
|---|---|---|---|---|---|
| Cover 100% of units | 4 kW | 7 | 4 kW | 517 units | 226 sq ft |
| Cover daytime use (about 55%) | 2.5 kW | 5 | 3 kW | 365 units | 161 sq ft |
The numbers you enter are your monthly units, your city and the panel wattage. The sunlight figure per city and the 15% roof allowance are our assumptions. Under net billing, units you use directly replace grid units priced at your full tariff, while exported units earn only a low credit. That is why the daytime-use size is a sensible starting point. Compare both sizes in the payback calculator.
How we size your system
- Daily units = monthly units ÷ 30.
- System kW = daily units × coverage ÷ your city's average daily output per kW (4.0 in Islamabad up to 5.0 in Quetta, after losses).
- Round up to the nearest 0.5 kW, then to whole panels.
- Pick the nearest standard inverter size (3, 4, 5, 6, 8, 10, 12, 15 or 20 kW).
- Roof space includes about 15% for walkways and row spacing.
On-grid, hybrid or off-grid?
- On-grid — cheapest; works only when the grid is on; best when load-shedding is rare.
- Hybrid — adds batteries for backup during outages and evenings; more expensive.
- Off-grid — no grid connection; needs a large battery bank; for remote sites.